Product
Engineered for comfort, convenient installation, and improved acoustic performance, our SPC flooring with pre-attached IXPE or EVA underlayment combines a rigid waterproof core with a resilient backing layer. The integrated pad helps reduce impact noise, improves underfoot comfort, and eliminates the need to install a separate underlayment.
Product Information
Engineered for comfort, convenient installation, and improved acoustic performance, our SPC flooring with pre-attached IXPE or EVA underlayment combines a rigid waterproof core with a resilient backing layer. The integrated pad helps reduce impact noise, improves underfoot comfort, and eliminates the need to install a separate underlayment.
| Characteristic | Test Method | Test Result |
|---|---|---|
| Dimensions | EN 427 | Not specified in the provided test sheet |
| Overall Thickness | EN 428 | 4.0 mm |
| Wear Layer Thickness | EN 429 | 0.30 mm |
| Peeling Strength of Layers | EN 431 | Pass |
| Shear Strength of Layers | EN 432 | Good |
| Residual Indentation after Static Load | EN 433 | Mean value: 0.01 mm |
| Dimensional Stability | EN 434 | Shrinkage: 0.002%; Curling: 0.2 mm |
| Flexibility – 10 mm Mandrel | EN 435 | No damage |
| Resistance to Chemicals | EN 423 | Class – specific grade not stated |
| Castor Chair Resistance | EN 425 | No disturbance; no delamination |
| Color Fastness to Light | ISO 105-B02 | ≥ 6 |
| Wear Resistance | EN 660 | Pass |
| Toxic Substances / Migration of Certain Elements | EN 71-3 | Complies |
| Fire Resistance / Surface Burning Performance | ASTM E84-03 | NFPA Class B |
| Slip Resistance Classification | DIN 51130 | R9 |
| Use Classification | EN 685 | Classes 23, 34 and 43 |
| PVC Tile Performance and Fire Classification | GB/T 4085 / GB 8624 Class B1 | Pass |
| PVC Tile Flame-Retardant Performance | CNS 8907 | Pass |